DESIGN PHASE: measurement SUB ELEMENT NAME: stability measurement VARIABLE NAME: [HEMSTAB] DATE: REVISION LETTER: REVISION DATE: APPLICABILITY: feedback circuits ACTIVITY: Measure and plot open loop and closed loop gain/phase. Specialized equipment usually necessary (Venable, Ridley, etc). OUTPUT: Measurements and plots in laboratory notebook for comparison to specifications and analysis. ALGORITHM: [HEMSTAB] = engineer hours for stability measurements [HTMSTAB] = technician hours for stability measurements 0.0+ set up time 0.0* hours per feedback loop [FEEDBACK LOOP COUNT]* number of feedback loops ([NWC]+ number of worse case measurement sets = 4 1) nominal condition measurement DISCUSSION: Worse case conditions for stability are usually: Minimum line, maximum load Minimum Line, minimum load Maximum Line, maximum load Maximum Line, minimum load Measurements are also usually taken at nominal conditions.
Original: Foutz, J., Power Supply Circuit Development Estimating Aid - An Expert System Application, IEEE Applied Power Electronics Conference Record, New Orleans, February 1-5, 1988. Revised 21 February 2001
Copyright © 2001 Jerrold Foutz