Spectrum Measurements

DESIGN PHASE:       measurement
SUB ELEMENT NAME:   spectrum measurement
VARIABLE NAME:      [HEMSPEC]
DATE:               REVISION LETTER:     REVISION DATE: 
APPLICABILITY:      switching mode circuit or rectifier circuit

ACTIVITY:  Make spectrum measurements of input current (e.g. 
Mil-Std-461 CE01, CE03 tests) and output voltage or current.

OUTPUT:  Measurements and plots in laboratory notebook for later
comparison to specification and analysis.

ALGORITHM:

[HEMSPEC] =    engineer hours for spectrum measurements
[HTMSPEC] =    technician hours for spectrum measurements
0.0+           set up time
0.0*           time per measurement plot
([INPUT COUNT]+[OUTPUT COUNT])  number of measurement plots

DISCUSSION:

Author: Jerrold Foutz, foutz@smpstech.com

Original: Foutz, J., Power Supply Circuit Development Estimating Aid - An Expert System Application, IEEE Applied Power Electronics Conference Record, New Orleans, February 1-5, 1988. Revised 21 February 2001