DESIGN PHASE: analysis SUB ELEMENT NAME: stability analysis VARIABLE NAME: [HEASTAB] DATE: REVISION LETTER: REVISION DATE: APPLICABILITY: feedback circuit ACTIVITY: Compute and plot open loop gain/phase and closed loop gain/phase of the circuit. OUTPUT: Gain/phase plots for comparison to requirements and measurements. ALGORITHM: [HEASTAB] = engineer hours for stability analysis 0.0+ set up time 0.0* hours per feedback loop [FEEDBACK LOOP COUNT]* number of feedback loops ([NWC]+ number of worse case condition sets 1) nominal DISCUSSION:
Original: Foutz, J., Power Supply Circuit Development Estimating Aid - An Expert System Application, IEEE Applied Power Electronics Conference Record, New Orleans, February 1-5, 1988. Revised 22 February 2001
Copyright © 2001 Jerrold Foutz