Reconcile Requirements, Analysis, and Measurements

DESIGN PHASE:       reconcile
SUB ELEMENT NAME:   reconcile
VARIABLE NAME:      [HER]
DATE:               REVISION LETTER:    REVISION DATE:   
APPLICABILITY:      all circuits, feedback circuits, regulator
                    circuits, switching-mode circuits, and circuits
                    with magnetics.

ACTIVITY:  Reconcile requirements, measurements, and analysis and
conduct prelayout design review.

INPUT:  Circuit requirements 
        Circuit measurements 
        Circuit analysis 

OUTPUT:  Reconciled set of key measurements and analysis with
requirements.  Conduct and document in letter for the prelayout
design review.

ALGORITHM:

[HER] =             engineer hours to reconcile measurement and analysis
[HERALL]+           engineer hours to reconcile all circuits
[HERFB]+            engineer hours to reconcile feedback circuits
[HERREG]+           engineer hours to reconcile regulation circuits
[HERSM]+            engineer hours to reconcile switching mode circuits
[HERMAG]            engineer hours to reconcile circuits with magnetics

[HTR] = [HTR*]      * as above

All circuits
============
[HERALL] =
0.0+                set up time
0.0*                time per part
[PARTS COUNT]       number of parts

[HTRALL] =          0.5*[HERALL]

Feedback circuits
=================
[HERFB] =
0.0+                set up time
0.0*                hours per feedback loop
[FEEDBACK LOOP COUNT]    number of feedback loops

[HTRFB] =           0.5*[HERFB]

Regulator circuits
==================
[HERREG] =
0.0+                set up time
0.0*                hours per regulation plot
[NR]                number of regulation plots

[HTRREG] =          0.5*[HERREG]

Switching-mode circuits
=======================
[HERSM] =
0.0+                set up time
0.0*                percentage of transient analysis hours
[HEATR]             hours for transient analysis

[HTRSM] =           0.5*[HERSM]

Magnetics circuits
==================
[HERMAG] =
0.0+                set up time
0.0*                number of hours per magnetic
[MAGNETIC COUNT]    number of magnetics

[HTRMAG] =          0.5*[HERMAG]

DISCUSSION:

Author: Jerrold Foutz, foutz@smpstech.com

Original: Foutz, J., Power Supply Circuit Development Estimating Aid - An Expert System Application, IEEE Applied Power Electronics Conference Record, New Orleans, February 1-5, 1988. Revised 24 February 2001