DESIGN PHASE: measurement SUB ELEMENT NAME: photo measurements - line, load, and reference transient measurement VARIABLE NAME: [HEMTL] DATE: REVISION LETTER: REVISION DATE: APPLICABILITY: feedback circuit or filter circuit ACTIVITY: Measure (take oscilloscope photographs) of step response and impulse response on all inputs (voltage stimuli, nominal to maximum and nominal to minimum and Mil-Std-461 CS06 if applicable) and step response on outputs (load stimuli, half load to full load, half load to no load, and +/- 10% at 90%, 50%, and 10% load) and step response on reference (square wave injected across reference diode or reference input with any filtering capacitors removed). OUTPUT: Labeled photographs in laboratory notebook for comparison to specifications and results of transient analysis (usually Spice plots under same conditions). ALGORITHM: [HEMTL] = engineer hours for feedback circuit transient response [HTMTL] = technician hours for feedback circuit transient response 0.0*( hours per measurement [INPUT COUNT]* number of inputs 2 + multiplier for step and input responses [OUTPUT COUNT]+ number of outputs 1) number of reference input measurements DISCUSSION:
Original: Foutz, J., Power Supply Circuit Development Estimating Aid - An Expert System Application, IEEE Applied Power Electronics Conference Record, New Orleans, February 1-5, 1988. Revised 25 February 2001
Copyright © 2001 Jerrold Foutz